Subxiphoid Tube Drainage In Pericardial Effusion Treatment

MUSA AĞRIŞ, ALİ SUAT ÖZDİŞ, KEMALETTİN HOŞGÖR, NİHAN KAYALAR, RAMİS ÖZDEMİR, YÜKSEL DERELİ

  • Year : 2011
  • Vol : 27
  • Issue : 4
  •  Page : 190-192
Inthisstudy,theoutcomes of subxiphoid pericardial tube drainage technique were eveluated in patients with pericardial effusion. 39 patients with pericardial effusion admitted toour clinic between January 2007 - December 2010 were treated with subxiphoid pericardial tube drainag etechnique. 16 of patients were femaleand 23 were male and their ages were between 17 to 83 years. The procedure was carried out with local anesthesia and sedation in all patients. There was no mortality in any patients. Average drainag evolume was 1050 ml. Recurrent pericardial effusion requiring repeated surgical in tervention was observed in 2 patients. Subxiphoid pericardial tube drainage is a effective and safetechnique for treatment of pericardial effusion.
Cite this Article As :
Description : None of the authors, any product mentioned in this article, does not have a material interest in the device or drug. Research, not supported by any external organization. grant full access to the primary data and, if requested by the magazine they agree to allow the examination of data.