Left to Right Shanting after Percutaneous Mit-ral Bakan Valvulopkısty (PMBV) Prevekınce and the Outcome

İsmet Dindar, Nuri Çağlar, Oktay Ergene, Ömer Kozan, MEHMET ÖZDEMİR

  • İsmet Dindar: Koşuyolu Kalp ve Araştırma Hastanesi
  • Nuri Çağlar: Koşuyolu Kalp ve Araştırma Hastanesi
  • Oktay Ergene: Koşuyolu Kalp ve Araştırma Hastanesi
  • Ömer Kozan: Koşuyolu Kalp ve Araştırma Hastanesi
  • MEHMET ÖZDEMİR: NECMETTİN ERBAKAN ÜNİVERSİTESİ
  • Year : 1992
  • Vol : 8
  • Issue : 3
  •  Page : 441-445
Left to right shunting immediately after and 6 months later the procedure was investigated in 22 patients who had undergone PMBV in Koşuyolu Heart and Research Hospital catheterization la-boratory. Oxymetric method was used for the de-tertion of shunting. Na left to rigt shunting was de-tected before PMBV. lmmediately after PMBV it was detected left to right shunting in eight cases (36.36%). The ratio of mam pulmonary w systemic (QpiQs)flow was Six mounths later cont-rol catheterization was peıformed and it was found that teli' ta right shunting in only 3 cases with a lower QpiQs ratio. It was concluded that PMBV can induce left to right shunting in a subtantial propardon of patients but üs cliııical importance is negligible.

Download Citation: Endnote/Zotero/Mendeley (RIS) RIS File

Download Citation: BibTeX BibTeX File

Conflict of interest : Yok
Selcuk Medical Journal
1992, Vol. 8 (3)
ISSN: 1017-6616
E-ISSN: 2149-8059
Received : , Accepted : , Published Online :