Various materials and techniques have been used to obtain an ideal graft ta replaced within the venous system in experimental "and ainica/ researches. In this study autogenous vein, spiral composite autogenous yein and knitted Dacron have been replaced segmentaly in canine femoral veins and the potantiality of these grafts has been investigated. Continuous patency was determined by venogram then by exploring on the fifteenth day. From the patency point of view autogenous vein was found to be significantly better than knitted Dacron (p< 0.01). And the spiral compsite ven was found to give better result than Dacron. Since long term observation was not avalible, recanalization could not be deminstrated.
Cite this Article As :

Download Citation: Endnote/Zotero/Mendeley (RIS) RIS File

Download Citation: BibTeX BibTeX File

Description : None of the authors, any product mentioned in this article, does not have a material interest in the device or drug. Research, not supported by any external organization. grant full access to the primary data and, if requested by the magazine they agree to allow the examination of data.