Testing retinal sensivitiy in ocular hypertension using automated colour perimetry

MEHMET OKKA, MEHMET KEMAL GÜNDÜZ

  • Yıl : 2000
  • Cilt : 16
  • Sayı : 3
  •  Sayfa : 189-191
The aim of this study was to compare the sensitivity of the white and the blue stimuli using macular full threshold and peripheral 60-4 testing strategies of the Humphrey field analyzer in patients with ocular hypertension. Ninety-eight eyes of 49 patients with ocular hypertension vvere examined using vvhite and blue stimuli. A decrease in retinal sensitivity in six eyes (6.12%) was more prominent in the macular full threshold and peripheral 60-4 threshold tests when the blue stimulus was used. The results show that these tests are important in detecting the early retinal damage.
Atıf yapmak için :
Açıklama : Yazarların hiçbiri, bu makalede bahsedilen herhangi bir ürün, aygıt veya ilaç ile ilgili maddi çıkar ilişkisine sahip değildir. Araştırma, herhangi bir dış organizasyon tarafından desteklenmedi.Yazarlar çalışmanın birincil verilerine tam erişim izni vermek ve derginin talep ettiği takdirde verileri incelemesine izin vermeyi kabul etmektedirler.