Value Of Glutathıon S-Transferase In Dıagnosıs Of Malıgnant Pleural Effusıons
Faruk Özer,Oktay İmecik,Bünyamin Kaptanoğlu,Kürşat Uzun
- Yıl : 1996
- Cilt : 12
- Sayı : 1
- Sayfa : 51-57
Özeti
Bu raltmada plorezili 89 hastanin plevra swat ve serumlan ile kontrol grubu olarak secilen 15 sag-hi& bireyin serumlartnda glwathion S-transferase (GST) diizeykri araprildt. Plikezinin nedeni 27 al-guda malignite iken 62 olguda malignite dip has-taliklarch. Maligniteli hasra grubunda elde edilen ortalama serum GST diizeyi 18.39±1.18 UIL olup gerek malignite dtsr plorezi grubu (p<0.01) ve ge-rekse kontrol grubundakikrden (p<0.001) anlamh derecede yiiksekti. Malignite ye malignite dui gruplarmda saptanan ortalama plevra smut GST diizeyleri strastyla 28.46±1.48 UIL ye 10.59±0.87 UIL olup aralanndaki fork istatistiksel olarak anlamh diizeydeydi (p<0.001). Maligniteli hasta gruhunun ortalama plevra stvistiserurn GST orant da diger hasta grubuna gore anlamh derecede viiksek bulundu. Malignite kaynakh plorezilerin ma-lignite dtp nedenlere bash olanlardan apt-- dedilmesinde 20 U1L'yi acan degerler kin plevra st-vist GST dikeyi tayininin spesifitesi % 97 ye sensitivitesi %85 olarak bulundu. Plevra sivesil serum GST orantnin spesifite ve sensitivitesi ise 1.4 stnir deter ile strastyla % 87 ve %78 idi. Bul-gulartmtz plevra mist GST diizeyi tayininin ma-lignite kaynakh plorezilerin tantsinda degerli hir M-celeme oldugunu gostermektedir.
We meauserd pleural fluid and serum glutathion S-tranferase (GST) activity in 89 patients with ple-ural effusion and serum GST activity in IS healthy person choosen as control group. The cause of 27 pleural effusion was malignancy, and nonmalignant diseases were determined as the cause of 62 cases. Mean serum GST activity was 18.39±1.18 UIL in patients with malignant effusions. which was sig-nificantly higher than those in both nonmalignant cases (p<0.01) and control group (p<0.001). Ple-ural fluid GST level of malignant and nonmalignant effusions were 28.46±1.48 U1L and 10.59±0.87 1.11 L. respectively. The difference between the pleural fluid GST values of malignant and nonmalignant ef-fusions was statistically significant (p<0.001). The mean pleural fluid to serum GST ratio of patients with malignant effusion was also significantly hig-her than that of nonmalignant group. The specifity and sensitivity of the determination of pleural fluid GST level in excess of 20 Ull. in distinguishing ma-lignant effusions were 97 percent and 85 percent, respectively. These values for pleural fluid to serum GST ratio with the cutoff level of 1,4 were 87 per-cent and 78 percent. Our findings indicate that de-termination of GST activity in pleural fluid has a di-agnostic value in differential diagnosis of malignant eiliisions.
Yazışma Adresi : Faruk Özer, Selçuk Üniversitesi Meram Tıp Fakültesi Göğüs Cerrahisi ABD
Eposta : [email protected]
Atıf yapmak için :
Açıklama :
Yazarların hiçbiri, bu makalede bahsedilen herhangi bir ürün,
aygıt veya ilaç ile ilgili maddi çıkar ilişkisine sahip değildir. Araştırma,
herhangi bir dış organizasyon tarafından desteklenmedi.Yazarlar çalışmanın
birincil verilerine tam erişim izni vermek ve derginin talep ettiği takdirde
verileri incelemesine izin vermeyi kabul etmektedirler.
None of the authors, any product mentioned in this article,
does not have a material interest in the device or drug. Research,
not supported by any external organization.
grant full access to the primary data and, if requested by the magazine
they agree to allow the examination of data.
Value Of Glutathıon S-Transferase In Dıagnosıs Of Malıgnant Pleural Effusıons, Araştırma makalesi,
1996,
Vol.
12(1)
Geliş Tarihi : 15.10.1996,
Kabul Tarihi : 15.10.1996
Selçuk Tıp Dergisi
ISSN: 1017-6616 ;
E-ISSN: 2149-8059 ;